6013L type digital capacitance meter is pocket, convenient operation, accurate numerical reading, low-consumption, driven by battery, and showing numbers in a big LCD. Being accurate in measuring, it covers 9 measuring sections, a wide rang from 0.1pF to 20,00μF. It can be used in testing error testing, numerical analysis, selecting capacitance, measuring unknown capacitance, matching capacitance, and measuring the capacitance of cable, switch and printing electrocircuit.
  • Item Description
  • Questions & Answers
  • Payment & Shipping

Features

6013L type digital capacitance meter is pocket, convenient operation, accurate numerical reading, low-consumption, driven by battery, and showing numbers in a big LCD. Being accurate in measuring, it covers 9 measuring sections, a wide rang from 0.1pF to 20,00μF. It can be used in testing error testing, numerical analysis, selecting capacitance, measuring unknown capacitance, matching capacitance, and measuring the capacitance of cable, switch and printing electrocircuit.
Wide measuring range, covering 9 measuring sections from 0.1pF to 20,00μF that includes nominal value of any capacitance.
Biggest display value: 1999(3 1/2).
Reading: 2-3 readings/sec.
Zeroing: There is a zeroing knob on the front, easy for operation.
Data hold: Put the “HOLD” switch to "ON" and the DH sign will appear on the display.
Temperature for accurate measuring: 25±5°C
Temperature range: working temperature: 0 to 40°C
Storage temperature: -10to 50°C
Relative humidity: <80%
Power supply:9V laminated battery(Not included)

Specification

Product details

Accuracy: ±(%reading±digits) Quality guarantee: one year
Environment temperature: 25℃±5℃
Relative humidity: <80%
Rang Accuracy Definition Testing frequency
200pF ±0.5% ±20digit 0.1pF 800Hz
2nF ±0.5%±20digit 1pF 800Hz
20nF ±0.5%±20digit 10pF 800Hz
200nF ±0.5%±20digit 0.1μF 800Hz
2μF ±0.5%±20digit 1nF 800Hz
20μF ±0.5%±20digit 10nF 80Hz
200μF ±0.5%±20digit 0.1μF 8Hz
2000μF ±2.0%±20digit 1μF 8Hz
Color:Grey+Red
Dimension:148 x 75 x 33 mm
Weight:173 g
Package weight:193 g

Package content 1 x Capacitance Tester
2 x Probes
Operation Firstly, check a 9V battery whether its electric voltage is short that will show signal on the left-upper of the LCD. Secondly, pay attention to the polarity or the capacitance to be tested. Thirdly, recharge the capacitance before measuring.

1. Select proper measuring section according to the capacitance to be tested.
2. Check and use the zeroing knob on the front of the meter to adjust the value to zero before measuring.
3. Insert the black sensor into the jack with “-”signal and the red sensor into the jack with “+”.
4. Connect the capacitance to be tested with the two sensors. Pay attention to the polarity of the capacitance ! Read capacitance numerical value displayed.
Notes a. If you don't know the approximate value of a capacitance, you should select measuring section of 200nF and then make relevant adjusting according to practical situation.
b. If the capacitance is in short circuit, the meter shows "beyond measuring range". If the capacitance is in electric leakage, the meter shows "beyond measuring range" or "much bigger than the normal value". If the capacitance is open-circuit, the meter shows "Zero" or "several pF ".
c. In testing small capacitance, directly insert the capacitance into the jack instead of using the sensors for better accuracy.
Maintenance The meter is of highly accurate electronic apparatus. Don't change its internal circuit rashly for no damage to the meter.

1. Don't exert electric voltage upon the jack parts of the meter for no damage to the meter.
2. Don't test the sensors in short circuit , or the battery will be consumed out quickly.
3. Don't use a meter whose back cover doesn't cover the meter well.
4. Always replace battery and fuse after taking sensors out of a meter that is switched off. First, screw bolts in the back cover out. Second, take off the back cover. Third, replace battery and fuse according to specification provisioned in the operation manual. Suitable fuse for this meter is 200mA/250V, which external dimension is φ5×20㎜.
5. Please take out the battery when not using for a long time.

Package Details
Weight: g
Size: cm
Package Includes
1 x Capacitance Tester;,2 x Probes

Credit Card

1, Please key in the correct shipping address in English while checking out with PayPal. Or the order will be shipped to your PayPal address.
2, If your home address (habitually receiving address) has been changed, please edit your PayPal address in time to avoid editing receiving address repeatedly while checking out with PayPal.
3, Normally, dropshipping order will be shipped out in 1 business day and non-dropshipping order 2 business days.

Shipping Method

Item Area Delivery time Delivery time
In Peak Season
Standard United States, Canada 15-20 calendar day 25-30 calendar days
Australia, New Zealand, Singapore, Vietnam, Malaysia, Israel,Indonesia, Turkey 20-25 calendar days 30-35 calendar days
Russia, United Kingdom, France, Spain, Germany, Netherlands, Spain, Ukraine, Japan, Belgium, Denmark, Finland, Ireland, Norway, Portugal, Sweden, Switzerland 25-30  calendar days 35-40  calendar days
Italy, Brazil, Argentina, Chile, Mexico 30-40 calendar days 40-50 calendar days
Priority United States, United Kingdom,Russia,Australia 7-15 calendar days 15-25 calendar days
Express 3-7 calendar days worldwide
What other people are saying
FocalPrice does not endorse, recommend or sponsor any guest product reviews.
5 star : 0
4 star : 0
3 star : 0
2 star : 0
1 star : 0
Average Rating: 5.0
0 customer reviews Write a Review, Post Images, or Post Videos, and get Focal Points.
Your Recent History Clear